Page 26
Operation Mode
TM-250 Miniature CCD Camera
time can be less than 11 lines for the TM-250 and 16 lines for the TM-260. If the F2 switch is Up (ON),
VSYNC is continuously generated and the camera behaves the same as in High-speed Cyclic shutter
operation. When F2 is OFF, VSYNC appears in only the field right after VINIT when F2 is down (OFF).
FIGURE 17. Pre-Reset Asynchronous Shutter Mode
TABLE 11. Shutter Speed Control in Pre-Reset Asynchronous Shutter Mode
F2
OFF
a
a. If F2 is up, VSYNC is continuously generated and the camera behaves the same as it does in high-
speed cyclic shutter mode.
F1
OFF
ASY
CYC
S3
0
S2
0
S1
0
S0
0
TRIGGER
Polarity
Exposure
Time
(sec.)
Up Up Up Down Down Down Up Negative 1/29,100
Up Up Up Down Down Up Down Negative 1/10,200
Up Up Up Down Down Up Up Negative 1/6,200
Up Up Up Down Down Down Down Negative 1/4,400
Up Up Up Down Down Down Up Negative 1/3,500
Up Up Up Down Down Up Down Negative 1/2,800
Up Up Up Down Down Up Up Negative 1/2,400
Up Up Up Up Down Down Down Negative 1/2,100
Up Up Up Up Down Down Up Negative 1/1,800
Up Up Up Up Down Up Down Negative 1/1,600
Up Up Up Up Down Up Up Negative 1/1,500
F2 Up: SYNC signal is continuous.
F2 Down: SYNC signal is available in one field right after VINIT.
Reset Reset
VINIT
Internal VD
DSUB pulse
Transfer
Exposure
Video Out