Page 12
Operation
TM-250 Miniature CCD Camera
3.2 External Sync
The TM-250 can accept external sync from an external sync generator or frame grabber. Its input
specifications are:
Internal/External auto switch
fH=15.734 KHz ±5%, fV=59.95 Hz ±5%
Note: The TM-250 has a one (1) horizontal line delay between the input VD signal and the
output video. If external vertical drive (VD) is applied to the camera, it may cause the
video output to be delayed 1 HD (1 HD = ~64.0 µs). If the imaging system is capable of
automatically detecting the start of video (within a few HD), then no problem will exist. If
it is not capable of automatically detecting the start of video, you may need to reconfigure
the video capturing sequence to delay video acquisition of 1HD.
FIGURE 3. Input Signals
HD
VD
3 - 5µsec
1 to 9HD
1/60
1/f(horizontal)
TTL Level
+5Volts
0 Volts
+5Volts
0 Volts
TTL Level
Comentários a estes Manuais