Page 20
Operation Mode
TM-250 Miniature CCD Camera
FIGURE 11. High-Speed Cyclic Shutter Mode Timing
5.1.3 Trigger Position Reset/Restart Shutter Mode
The shutter trigger pulse (TRIG) needs to synchronize with Reset-Restart (EXT VD) pulse. It should be
2 lines or more in width. The leading edge of TRIG pulse produces DSUB (discharge) pulse and starts
the exposure. The transfer (read-out) occurs at the 11th line after EXT VD pulse is fed. A full picture
field can be obtained in every field. The TRIG must be wider than one line.
Video Out
Internal VD
DSUB pulse
Transfer
Exposure