Page 10
Operation
TM-250 Miniature CCD Camera
TABLE 3. Shutter Speed Control in Post-Reset Asynchronous Shutter Mode
Switch Position
Shutter Speed (Sec.)
F1
OFF
ASY
CYC
S3
0
S2
0
S1
0
S0
0
Down Up Down Down Down Up 1/60
Down Up Down Down Up Down 1/120
Down Up Down Down Up Up 1/250
Down Up Down Up Down Down 1/500
Down Up Down Up Down Up 1/1,000
Down Up Down Up Up Down 1/1,600
Down Up Down Up Up Up 1/1,800
Down Up Up Down Down Down 1/2,100
Down Up Up Down Down Up 1/2,400
Down Up Up Down Up Down 1/2,800
Down Up Up Down Up Up 1/3,500
Down Up Up Up Down Down 1/4,400
Down Up Up Up Down Up 1/6,200
Down Up Up Up Up Down 1/10,200
F2 Up: SYNC signal is continuous.
F2 Down: SYNC signal is available in one field right after VINIT.
TABLE 4.
Shutter Speed Control in Pre-Reset Asynchronous Shutter Mode
Switch Position
Shutter Speed (Sec.)
F1
OFF
ASY
CYC
S3
0
S2
0
S1
0
S0
0
Up Up Down Down Down Up 1/29,100
Up Up Down Down Up Down 1/10,200
Up Up Down Down Up Up 1/6,200
Up Up Down Up Down Down 1/4,400
Up Up Down Up Down Up 1/3,500
Up Up Down Up Up Down 1/2,800
Up Up Down Up Up Up 1/2,400
Up Up Up Down Down Down 1/2,100
Up Up Up Down Down Up 1/1,800
Up Up Up Down Up Down 1/1,600
Up Up Up Down Up Up 1/1,500
F2 Up: SYNC signal is continuous.
F2 Down: SYNC signal is available in one field right after VINIT.