Pulnix TM-250 Manual de Instruções Página 21

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 20
Page 15
Operation
TM-250 Miniature CCD Camera
The following four asynchronous shutter modes are available:
Strobe Asynchronous Shutter Mode
Pre-Reset Asynchronous Shutter Mode
Post-Reset Asynchronous Shutter Mode
Pulse Width Asynchronous Shutter Mode
Please contact PULNiX for timing charts of various asynchronous shutter modes.
3.3.4 External Sync Mode
TM-250 accepts standard RS-170 external sync, which is defined as horizontal sync (HD) and vertical
sync (VD). The phase-locked loop jitter is designed to be the minimum (< 5ns) in this category using
the latest PLL chip. The wide capture range enables the camera to operate at an extended temperature
range (optional) of -35°C to 65°C. HD and VD input is TTL level and the high impedance is 100K or
75 (optional).
3.3.5 Reset-Restart Mode
Rather than using VINIT as asynchronous reset, the camera can be reset using EXT VD. In this mode,
the camera needs multiple VD pulses to output valid images, depending on whether it is set to Field or
Frame mode. Usually, the first field (Field mode) or the first frame (Frame mode) are garbage because
of previous signal residuals prior to reset. A frame grabber has to know which frame or field to capture.
External HD must be applied for this operation.
3.3.6 External Shutter Control
The shutter speed or exposure can be controlled with external pulse (TRIG) in this mode. In
combination with Reset-Restart Pulse (EXT VD), the camera can be externally controlled for image-
capture timing as well as for exposure time.
This is an excellent application for capturing multiple images (two fields of images) of indexing objects
under various lighting or brightness conditions. When Frame mode is selected, the full vertical
resolution is achieved by taking two fields of shutter images, whether or not you are using an electronic
shutter.
3.3.7 Integration
When integration control (VINIT) is low, the CCD imager keeps integrating. When the signal returns to
high, it enables the charge transfer for video output. This mode integrates longer than one field. With
strobe light application, it can capture randomly strobed images during the integration. It also increases
the exposure time to enhance low-light viewing.
3.3.8 Non-Interlace Operation
With non-interlace external sync, the camera operates at non-interlace scanning. External VD must be
generated at integer of 262H ± 8H. (Standard interlace is 262.5 H)