Page 25
VIS CAM 300/400 Installation Manual
Installing the Vehicle Imaging System
3.3.4 X8 LS RS485 Out Connector
The RS485 output from the Light Sensor to the RS485-to-Ethernet converter connector is X8. The
connections from X8 to the converter are shown in Table 6 and Figure 23
TABLE 6. X8 to converter connector
FIGURE 23. Wiring for the X8 to converter connector.
Up to four cameras can be connected to one Light Sensor using one Moxa Nport 5232 Device Server. If
more than four cameras need to be connected to the same Light Sensor please refer to “Appendix E:
Moxa N-Port 5232 Configuration” on page 93 in this Manual.
X8 Pin # Signal Description Connection to RS485-to-Ethernet converter
1
+24V
dc
24V Power output
V+ power input
2 Gnd Power return V- power input
3
+12V
dc
12V Power output
4Gnd
Power return
5 D0+ RS485 databus D0+ D+ Port 2
6 D0- RS485 databus D0- D- Port 2
7 D1+ RS485 databus D1+ D+ Port 1
8 D1- RS485 databus D1- D- Port 1