7.8 Problem 8: Night Time Image is Too Bright and License Plate is Whited Out
or Saturated
1. Make sure that the light sensor is connected to the EN camera (Set ADR register to Auto).
2. Add ADR A offset to reduce the gain at night time. ADR offset is used only when the night light is
turned on. When ADR A offset is high, the EN camera reduces the system gain and the brightness
of the license plate is reduced. Add only to ADR A offset.
7.9 Problem 9: Timestamp is Not Set to Current Local Time
1. Use the EN setup software to set local time. In the “Property” window, find the “Real Time Clock”
register. If NTP is OFF, then the displayed time is estimated to drift about 1.5 second per day.
2. If NTP is ON, then the time is automatically synchronized with the NTP server. However, the
timestamp inside the TIF/JPEG header is UTC in GMT time zone. The viewers software will need
to decode the UTC (GMT time zone) to sync appropriately with local time.
7.10 Information and Support Resources
For further information and support:
Phone: (408) 383-0300