TS-9720EN Series Progressive Scan Shutter Cameras
Page 31
Uploading the Firmware
4. Select “Update H8.”
5. Reboot the EN camera for the changes to take effect.
4.7 Updating the Firmware Manually When the Network is Down
It is sometimes necessary to update the firmware by hand when you do not have access to the network.
This can happen, for example, if you have forgotten the IP address of the camera or when the update via
the network fails. To update the firmware by hand, follow the steps below. You will need to use the
RS-232 serial cable and the power/serial debug cable.
1. Log-in (user=root, password=JAIPULNiX) and change the directory to /usr/local/bin.
2. Type “ps” to see the process running. Kill the “dhcpcd” process, if it is running in the background.
3. Assign a static IP address to the network interface.
Example: To assign a static IP=10.0.0.65 and subnetmask =255.255.255.0, enter the fol-
lowing command:
ifconfig eth0 10.0.0.65 netmask 255.255.255.0
4. Via FTP, manually send the firmware file to the /usr/local/bin directory of the EN camera.
5. Run test_bcs utility.
Ex.test_bcs –a en_YYMMDDVR.app Update EN App file
test_bcs -b xc2s200e_YYMMDDVR.bin Update FPGA bitfile
test_bcs -l libdrv_YYMMDDVR.drv Update Lib/Drv file
test_bcs -o vmlinuz_YYMMDDVR.osi Update OS image
6. Reboot the EN camera (command “reboot”). The new firmware is loaded at the next power-up.