3.9 Camera Timing Charts
Model: TM-4000 Operation Mode: Dual Tap Output
Master Clock: 80.000 MHz, M=12.5 nsec
Pixel Clock: 40.000 MHz, P= 25.0 nsec
1. Pixel Clock and Digital Data
Tcd
Tdc
Thd
Tcd: Clock to Data Ready
Tdc: Data Ready to Next Clock
Thd: Data Hold Time
Pixel Clock
Data
A
Tcd = 12.5 nsec, Tdc = 12.5 nsec, Thd = 7 nsec.
2. Horizontal Signals Timing
External HD
Internal HD
LDV
Digital Data
Analog Video
fHD = [ 30.78 KHz]
tHD = [ 32.5 µsec]
A [ 100 P],( 2.50 µs)
C [ 1300 P], ( 32.5 µs)
B [ 1200 P], ( 30.0 µs)
F [ 1300 P], ( 32.5 µs)
E [ 1024 P], ( 25.6 µs)
D [ 276 P], ( 6.90 µs)
G [ 0 P], ( 0.0 µs)
H [ 276 P], ( 6.9 µs)
I [ 1024 P], ( 25.6 µs)
J [ 176 P], ( 4.40 µs)
K [ 1024 P], ( 25.6 µs)
L [ 100 P], ( 2.50 µs)
M [ 100 P], ( 2.50 µs)
N [ 100 P], ( 2.50 µs)
Comentários a estes Manuais