INSTALLATION
Page 6 TM-7200/TM-6200 High Resolution Digital CCD Camera
2.2.3 (b) PULNiX Power Cables
If you are using PULNiX power cables, such as the 12P-02, KC-10, etc., please refer to the pin-out
diagram. The color coded leads use Grey for Ground and Yellow for +12V DC.
FIGURE 2.
12P-02 Interface Cable (optional)
Note:
Make sure that the unused leads are not touching and that there is no possibility that the
leads could short due to exposed wires.
2.2.3 (c) “K” Series Power Supplies
Attach the 110V line cord to the two terminals marked “AC”. Do not plug the cord into a 110V AC
socket until later in the procedure. Next, attach the Grey and Yellow leads of the power cable to the
Ground and 12V DC terminals respectively. Be sure to replace the plastic terminal guard on the power
supply at this time.
Note:
The “K” series power supplies are designed primarily for OEM users who will be
mounting the power supply inside a protective enclosure. For use in exposed situations,
the DC-12N and PD-12 are recommended.
2.2.3 (d) Building Your Own Power Cable
Consult the pin-out for the camera purchased. Connect the Ground and +12V power leads of the PC-
12P power connector to Pin #1 and Pin #2, respectively (power must be DC regulated and of sufficient
current to properly power the camera).
12P-02 Interface Cable
Pin# Lead Color Function Pin# Lead Color Function
1 Gray GND 7 Black coax VD Input
2 Yellow +12VCD 8 White coax shield GND
3 Red coax shield GND 9 White coax HD Input
4 Red coax Video 10 Brown GND
5 Orange coax shield GND 11 Blue Int. Cont.
6 Orange coax VINIT 12 Black coax shield GND
1
32mm
2,000mm± 10mm
(2 Meters)
PC-12P (Hirose Part #10A-10P-12S/PC12P)
Flying
Leads
1