Operating Modes
The TM-250NIR/TM-260NIR operates in the following
modes that can be selected by the DIP switch on the rear
panel of the camera.
Standard Interlace Mode
Field Mode and Frame Mode
The field and frame integration mode is selectable.
Frame integration is used to separate all CCD pixels and
exposure of Odd and Even fields generates the full frame
image shown in the figure below.
Field Mode Binning
Field integration is done by combining two pixel rows
(binning) together, each pair alternating as an interlace
scan is generated. Row 1 is binned with row 2, and row
3 is binned with row 4. In Field 2, row 2 is binned with
row 3, row 4 with row 5, and so on. Field mode is very
effective in shutter mode because the pixel sensitivity is
doubled for field integration (1/60 sec) and equals frame
mode (one row at 1/30 sec). Because Shutter mode is
only one field output per shutter, and darker than nor-
mal image, two-row binning is effective. This mode also
reduces interlace moire when a sharp horizontal pattern
is observed. For higher pixel definition such as gauging
and sub-pixel interpolation, Frame mode operation is
recommended.
External Sync Mode
The TM-250NIR/TM-260NIR accepts standard RS-
170 external sync, which is defined as horizontal sync
(HD) and vertical sync (VD). Phase-locked loop jitter
is designed to be the minimum (< 5ns) in this category
using the latest PLL chip. The wide capture range
enables the camera to operate at an extended tempera-
ture range (optional) of -35°C to 65°C. HD and VD input
is TTL level and the high impedance is 100KΩ or 75
(optional).
Non-Interlace Operation Mode
With external sync of non-interlace, the camera oper-
ates at non-interlace scanning. External VD must be
generated at integers of 262H ± 8H. (Standard interlace
is 262.5 H)
Cyclic (Continuous) Shutter Mode
With back-plate shutter control, the TM-250NIR/
TM-260NIR operates at the internally predefined shutter
speeds. Each field output is exposed for the same peri-
od. The shutter control varies the substrate discharge
timing. The duration between the shutter pulse and
transfer gate timing (11H* from VD edge) decides the
exposure time. (*16H for CCIR) The following three cyclic
shutter modes are available:
High-Speed Cyclic Shutter mode
Trigger Position Reset/Restart Shutter mode
Trigger Width Reset/Restart Shutter mode
Contact JAI PULNiX for timing charts of various cyclic
shutter modes.
Asynchronous Reset & Asynchronous Shutter
By supplying VINIT pulse on pin #6, the camera can be
reset asynchronously. In this mode, when VINIT is kept
high, it continuously discharges the CCD and outputs
the field video signal upon the negative going edge. The
output stays continuous during VINIT low. The first field
output is always Odd.
The following four asynchronous shutter modes are
available:
Strobe Asynchronous Shutter Mode
Pre-Reset Asynchronous Shutter Mode
Post-Reset Asynchronous Shutter Mode
Pulse Width Asynchronous Shutter Mode
Please contact JAI PULNiX for timing charts of various asyn-
chronous shutter modes.
Reset-Restart Mode
Rather than using VINIT as async reset, the camera
can be reset using EXT. VD. In this mode, the camera
needs multiple VD pulses to output valid images depend-
ing on whether it is set to Field or Frame mode. Usually,
the first field (field mode) or first frame (frame mode)
is garbage because of previous signal residuals prior to
reset. A frame grabber has to know which frame or field
to capture. External HD must be applied for this
operation.
Reset-Restart with Electronic Shutter
The shutter speed or exposure can be controlled with
external pulse width control or external pulse position
control in this mode. In combination with Reset-Restart
pulse (EXT. VD), the camera can be externally controlled
for the image-capture timing as well as the exposure
time.
This is an excellent application for capturing multiple
images (two fields of images) of indexing objects under
various lighting or brightness conditions. When Frame
mode is selected, the full vertical resolution is achieved
1
2 3
261
262
263
264
524
525
261 262
263
264
524
525
1
2 3
1
2
3 261
262
263
264
524
525
HD
VD
Odd
Field
Even
Field
Odd Odd OddEven Even Even
Odd Odd OddEven Even Even
Frame Integration
Field Integration
Even
Field
Odd
Field
Even
Field
Odd
Field









 


































 

 

























