OPERATION
TM-1300 Progressive Scanning High Resolution Camera Page 13
FIGURE 4. Internal Reset Mode
3.1.2 Asynchronous Shutter
For Async Shutter mode, select mode control switch #2 and press the up/down switch down. When the
negative going reset pulse VINIT is applied to pin 6 of the 12-pin connector, the camera will latch the
falling edge to its next horizontal drive and immediately reset the vertical sync timing. Therefore, the
horizontal pulse phase will not be interrupted.
The TM-1300 asynchronous camera outputs a full frame of shuttered video in progressive scanning
format from a frame buffer. The frame buffer is updated with each new image captured upon receiving
the next negative reset pulse. Since the internal frame buffer is designed to capture asynchronously
triggered images and output them as continuous video, an ordinary frame grabber can be used with the
TM-1300 (some frame grabber boards cannot accept disrupted sync).
The scan converted analog output is continuous sync without interruption at the trigger point. Therefore,
a computer monitor can display steady images without losing sync or jumping images.
Note: All trigger input signals should have a pulse width of 160µsmin. (2H) 80ms 1000H max.
for the camera to function properly.
External pulse
Hd
Internal Vinit
Transfer Gate
Pulse
Purge pulse
(discharge)
X
Exposure Time
min. 2H
Shutter Speed
CCD
VD